The auto-ranging, True RMS power meter is designed for today's electrical
environments. Operation is simple. There are no programming requirements
or menus, just four pushbuttons for direct access. The Model 3910 is also
auto-ranging, and ensures the best range for measurements.
Troubleshooting and measuring power is done simply by connecting two
voltage leads and clamping on the current probe. The Model 3910 performs
current and voltage measurements in True RMS, and provides immediate
readings of Power Factor (PF), Active Power (kW), Reactive Power (kVar),
Apparent Power (kVA) and Frequency (Hz).
The Model 3910 is housed in a protective holster, and comes ready for
field use with test leads, test probes, and 500AAC current probe in a
rugged carrying case. A 1000A probe is optional. |
 |

-
True RMS measurements for distorted waveform environments.
- Selectable single-phase and three-phase settings.
- Direct display of multiple measurements for easy reading.
-
Measures directly Arms, Vrms, PF, kW, kVar, kVA and Hz.
- Peak and memory functions for load analysis.
- Simple, user-friendly operation.
- Large format display.
- Built to IEC348 safety standards.
- Compact and rugged instrument complete with 500A current
probe and safety rubber housing.
- Supplied with a hard carrying case.

-
Performs a wide array of power measurements.
-
Quality control applications to measure power on electronic
and motor circuits.
-
Analysis of load demand.
-
Determine peak periods and line loads.
-
Conduct energy management and power factor surveys.
-
Power factor correction.
Model 3910 Datasheet
PDF (200kb) |
|
 |
| |
| Model |
3910 |
| Measurement |
Range |
Accuracy |
Current (True RMS)
|
1 to 500Arms
(1000A*)
|
| With supplied probe |
|
25.0A: |
±5% of Reading, Phase 4° |
|
100A: |
±2% of Reading, Phase 2° |
|
500A: |
±2% of Reading, Phase 1.5° |
|
Voltage (True RMS)
|
1 to 600Vrms
|
|
1 to 99.9V: |
0.5% of Reading ±0.6V |
|
100 to 600V: |
0.3% of Reading ±2V |
|
Frequency (Hz)
|
30 to 100Hz
101 to 1000Hz |
0.03% of Reading ±0.1Hz
0.03% of Reading ±1Hz |
Power Factor
|
-0.00 (10g) to
±0.00 (lead) |
Sum of the V and A accuracy
plus the probe phase shift |
Active Power
|
30 to 300kW
(600kW*) |
Sum of the V and A accuracy
|
Reactive Power
|
30 to 300kVar
(600kVar*) |
Sum of the V and A accuracy
@ sin1=1 plus the probe phase shift |
Apparent Power
|
30 to 300kVA
(600kVA*) |
Sum of the V and A accuracy
|
|
| Note: * with optional 1000A Clamp-on current
probe. |
| |
| |
 |
| |
| Catalog Number |
Description |
2111.27
|
Model 3910 True RMS Power Meter with 500A probe and
carrying case. |
|
| |
| |
|
 |
Model 3910 includes new high
impact carrying case, 500A probe, one red and one black lead, one red and
one black test probe, one red and one black grip probe and user manual. |
|
|