Navigation:
AEMC Products>
Cable Testers >
CA7024 |
| |
|
|
| |
 |
| |
|
The Fault Mapper Model CA7024 is a
hand-held, alphanumeric, TDR (Time Domain Reflectometer) Cable Length
Meter and Fault Locator, designed to measure the length of electrical and
communication cables. It can also indicate the distance to a fault in the
cable (open or short), given access to only one end of a two or more
conductor cable. By incorporating fast-edge step TDR technology, the Model
CA7024 measures cable length and indicates the distance to open or short
circuit faults. to a range of 6000 ft (2000m), on virtually any type of
cable. The Model CA7024 indicates the cable length or fault distance and
description, alphanumerically on a 128 x 64 graphical LCD.
|

|

- Detects opens, shorts and the distance between them.
- Measure cable length up to 6000 ft (2000m).
- Built-in library of most common cables and their Vp (Velocity of
Propagation).
- Manual selection of Vp for all cables not found in library.
- Vp setting displayed along with length and cable type (if in
library).
- Automatic cable impedance compensation.
- Built-in tone generator for tracing and locating cables.
- Large high-visibility blue electroluminescent backlit display.
- CE Mark.

- Determine length of cables on reels, coils or in boxes.
- Determine cable runs in wall, conduit and other surfaces.
- Detect opens and shorts in cables and the length to them.
- Trace cables to identify runs and location.
|
|
|
|
|

Model TR02 (accessory)
|

Model CA7024 includes meter, soft carrying case,
BNC pigtail cable with alligator clips,
4 ea 1.5V AA batteries and user manual.
|
|
| |
| |
 |
| |
|
Range @ Vp
= 70% |
6000 ft (2000m) |
|
Resolution |
0.1 ft up to 100 ft, then 1 ft (0.1m up to
100m, then 1m) |
|
Accuracy |
± 2% of Reading |
|
Minimum Cable Length |
12 ft (4m) |
|
Cable Library |
Built-in, operator selectable |
|
Vp (Velocity of Propagation) |
Adjustable from 0 to 99% |
|
Output Pulse |
5V (peak to peak) into open circuit;
ns rise Step Function |
|
Output Impedance |
Automatic compensation |
|
Display Resolution |
128 x 64 pixel graphical LCD |
|
Tone Generator |
Oscillating 810Hz to 1110Hz |
|
Voltage Warning |
Triggers at >10V AC/DC |
|
Power Source |
4 ea 1.5V AA Alkaline Batteries |
|
Auto-Off |
After 3 minutes |
|
Weight |
12oz (350g) |
|
| |
| |
 |
| |
|
Catalog No. |
Description |
|
2127.80
|
Model CA7024 Fault MapperTM
(Cable Length and Fault Locator -
Alphanumeric TDR). |
|
2127.75 |
Model TR02 Tone Receiver/Cable Tracer |
|