The Hipot Tester Model H216 is designed for
AC/DC Withstanding Voltage Testing and Insulation Resistance Testing (IR)
providing a safe and accurate test environment for the operator. The Model
H216 complies with the requirements of the electrical equipments and
appliance testing standard, UL, CSA and other international standards. The
Model H216 can be used for withstanding voltage tests of the various types
of electrical equipment and components. The Model H216 provides AC hipot
programmable to 5kV @ 40mA and DC hipot programmable to 6kV @ 10mA.
|

|

- AC Hipot programmable to 5kV @ 40mA.
- DC Hipot programmable to 6kV @ 10mA.
- Continuity measurement @ 100mA.
- Insulation Resistance to 9900<Ω @ 500VDC and 1000VDC and to 1990MΩ
@ 50V/100V.
- ARC current detection with programmable limits.
- Programmable ramp, test and wait times, output voltages and trip
limits.
- Selectable AC test frequency (50Hz and 60Hz).
- Set trip current setting without loads or high voltage present.
- Automatic testing - store up to 10 tests (up to 16 steps per
test).
- Line and load regulation for linear output voltage.
- Highly visible warning light indicator for HV output.
- Pass and fail lights with adjustable buzzer.
- Program lock-out feature to prevent user error or program changes.
- PLC remote control (9 pin connector); serial communication port (9
pins).
- Includes HV Test Pistol Model SP02 and black grounding lead.

- Test dielectric strength of electrical insulation.
- Test ground circuit continuity of 3-wire appliances and devices.
- Detect workmanship defects such as nicks in wires and components
mounted incorrectly.
- Locate defective components.
- Measure insulation resistance.
|
|
|
 |
| |
|
 |
|
Voltage Range |
100V to
5000VAC (5kV) |
|
Voltage Step
Resolution |
5V |
|
Voltage Regulation |
±1% of Reading
±5V |
|
Accuracy |
±1% of Reading
±10V (>500V) |
|
Test Frequency |
50Hz or
60Hz (selectable) |
|
Current |
0.10mA to
40mA in 0.02mA steps |
|
Maximum Current Output |
40mA @
5kV |
|
Accuracy |
±1% of Reading
±50V/A |
|
Ramp and Test Time |
0.000s to
999.9s |
|
| |
| |
|
 |
|
Voltage Range |
100V to
6000VDC (6kV) |
|
Voltage Step
Resolution |
5V |
|
Voltage Regulation |
±1% of Reading
±5V |
|
Accuracy |
±1% of Reading
±10V (>500V) |
|
Trip Current |
0.10mA to 10mA in 0.01mA steps |
|
Maximum Current Output |
10mA @ 6kV |
|
Accuracy |
±1% of Reading
±50µA |
|
Ramp and Test Time |
0.000s to 999.9s |
|
| |
| |
|
 |
|
DC Test Voltage |
50V and
100V; 500V and 1000V |
|
Measurement Range
|
1 to 1990MΩ
1 to 9900MΩ |
|
Accuracy |
1 to 500MΩ |
| |
501MΩ
to 2000MΩ |
|
|
±5% of Reading |
|
±10% of Reading |
|
|
Test Time |
0.000s to 999.9s |
|
| |
| |
|
 |
|
Resistance Range |
0.001Ω
to 1,500Ω |
|
Test Current |
100mA
(0.1A) |
|
Detect Accuracy |
0.1Ω
@ 0.1Ω |
|
Test Time |
0.000s to 999.9s |
|
| |
| |
|
 |
|
Detect Current |
Selectable in 1mA steps from 2 to 40mA |
|
| |
| |
 |
| |
|
Catalog Number |
Description |
|
2129.63
|
Model H216 Hipot Tester
(5kVAC/6kVDC and IR, including HV Test Pistol 6ft model SP02 and black grounding lead) |
|
| |
| |
| |
 |
| |
|
Catalog Number |
Description |
|
2117.89 |
HV Test Lead 9ft
(un-terminated, 3m) |
|
| |

|

|
|
Model H111
Includes HV Test Pistol (6ft)
SP02 and black grounding lead. |
Optional HV Test Lead 9ft (3m)
(un-terminated without test pistol)
Catalog #2117.89 |
|