The Hipot Tester Model H216 is designed for AC/DC Withstanding Voltage Testing and Insulation Resistance Testing (IR) providing a safe and accurate test environment for the operator. The Model H216 complies with the requirements of the electrical equipments and appliance testing standard, UL, CSA and other international standards. The Model H216 can be used for withstanding voltage tests of the various types of electrical equipment and components. The Model H216 provides AC hipot programmable to 5kV @ 40mA and DC hipot programmable to 6kV @ 10mA.
 

 

 

 

 

 

 

 

 

 

 

  • AC Hipot programmable to 5kV @ 40mA.
  • DC Hipot programmable to 6kV @ 10mA.
  • Continuity measurement @ 100mA.
  • Insulation Resistance to 9900<Ω @ 500VDC and 1000VDC and to 1990MΩ @ 50V/100V.
  • ARC current detection with programmable limits.
  • Programmable ramp, test and wait times, output voltages and trip limits.
  • Selectable AC test frequency (50Hz and 60Hz).
  • Set trip current setting without loads or high voltage present.
  • Automatic testing - store up to 10 tests (up to 16 steps per test).
  • Line and load regulation for linear output voltage.
  • Highly visible warning light indicator for HV output.
  • Pass and fail lights with adjustable buzzer.
  • Program lock-out feature to prevent user error or program changes.
  • PLC remote control (9 pin connector); serial communication port (9 pins).
  • Includes HV Test Pistol Model SP02 and black grounding lead.

  • Test dielectric strength of electrical insulation.
  • Test ground circuit continuity of 3-wire appliances and devices.
  • Detect workmanship defects such as nicks in wires and components mounted incorrectly.
  • Locate defective components.
  • Measure insulation resistance.
 

Voltage Range

100V to 5000VAC (5kV)

Voltage Step Resolution

5V

Voltage Regulation

±1% of Reading ±5V

Accuracy

±1% of Reading ±10V (>500V)

Test Frequency

50Hz or 60Hz (selectable)

Current

0.10mA to 40mA in 0.02mA steps

Maximum Current Output

40mA @ 5kV

Accuracy

±1% of Reading ±50V/A

Ramp and Test Time

0.000s to 999.9s
 
 

Voltage Range

100V to 6000VDC (6kV)

Voltage Step Resolution

5V

Voltage Regulation

±1% of Reading ±5V

Accuracy

±1% of Reading ±10V (>500V)

Trip Current

0.10mA to 10mA in 0.01mA steps

Maximum Current Output

10mA @ 6kV

Accuracy

±1% of Reading ±50µA

Ramp and Test Time

0.000s to 999.9s
 
 

DC Test Voltage

50V and 100V; 500V and 1000V

Measurement Range
 

1 to 1990MΩ
1 to 9900MΩ

Accuracy

1 to 500MΩ

 

501MΩ to 2000MΩ

±5% of Reading
±10% of Reading

Test Time

0.000s to 999.9s
 
 

Resistance Range

0.001Ω to 1,500Ω

Test Current

100mA (0.1A)

Detect Accuracy

0.1Ω @ 0.1Ω

Test Time

0.000s to 999.9s
 
 

Detect Current

Selectable in 1mA steps from 2 to 40mA
 
 
 

Catalog Number

Description

2129.63
 

Model H216 Hipot Tester (5kVAC/6kVDC and IR, including HV Test Pistol 6ft model SP02 and black grounding lead)

 
 
 
 

Catalog Number

Description

2117.89

HV Test Lead 9ft (un-terminated, 3m)

 


 


 

Model H111
 Includes HV Test Pistol (6ft)
SP02 and black grounding lead.

Optional HV Test Lead 9ft (3m)
(un-terminated without test pistol)
Catalog #2117.89


 

AEMC | AMPROBE | CIE | FLUKE | HT ITALIA | HODEN | PROVA | POMONA | RAYTECH |  SILVERTRONIC
Home | PRODUCTS | SEARCH
Obiat Pty. Ltd.
A.C.N. 003 166 952      A.B.N. 23 003 166 952
Unit 9A/8 Avenue of the Americas, Newington NSW 2127 Australia
P.O. Box 6901 Silverwater  NSW Australia 1811

Phone: 61-2-9748- 8699

Fax: 61-2-9748-8544

E-mail:
 