DC Volt |
|
Voltage Ranges |
400mV, 4V, 40V, 400V, 600V |
|
Resolution |
0.1mV |
|
Accuracy |
±(0.5% of rdg. + 2
digits) |
|
Input Impedance |
400mV: >100MΩ;
4V:10MΩ; 40V to 600V: 9.1MΩ |
|
mV Range Measurement |
to measure millivolts use "RANGE" button
to manually select 400mV range. |
|
Overload Protection |
600V DC or AC rms. |
|
|
|
|
|
|
|
AC Volt (50Hz to 500Hz) |
|
Voltage Ranges |
400mV, 4V, 40V, 400V, 600V |
|
Resolution |
1mV |
|
Accuracy |
±(1.2% of rdg. + 5
digits)
±(1.5% of rdg. + 5 digits) on 600V range |
|
Input Impedance |
4V:10MΩ;
40V to 600V: 9.1MΩ |
|
Overload Protection |
600V DC or AC rms. |
|
|
|
|
|
|
|
AC Current (50Hz to
500Hz) |
|
Current Ranges |
40A, 400A |
|
Resolution |
0.01A |
|
Accuracy |
±(2.0% of rdg. + 6
digits) |
|
Overload Protection |
400A AC |
| |
|
| |
|
|
Resistance |
|
Resistance Ranges |
400Ω, 4kΩ, 40kΩ,
400kΩ, 4MΩ, 40MΩ |
|
Resolution |
0.1Ω |
|
Accuracy |
±(1.0% of rdg. + 4
digits) on 400Ω to 400kΩ ranges
±(1.5% of rdg. + 4 digits) on 4MΩ range
±(3.0% of rdg. + 5 digits) on 40MΩ range |
|
Open Circuit Volts |
-0.45V DC typical, (-1.2V DC on 400Ω
range) |
|
Overload Protection |
600V DC or AC rms |
|
|
|
| |
|
|
Capacitance |
|
Capacitance Ranges |
4µF, 40µF, 400µF,
4mF |
|
Resolution |
1nF |
|
Accuracy |
±(3.0% of rdg. + 15
digits) on 4µF range.
±(3.0% of rdg. + 5 digits) on 40µF to 400µF ranges.
±(5.0% of rdg. + 20 digits) on 4mF range. |
|
Minimum Input Range |
< 100nF |
|
Overload Protection |
600V DC or AC rms. When the capacitor to
be tested is connected, and if "dsc" symbol is displayed it means
that there is voltage existing in the capacitor and it must be
discharged first, before testing can be done. |
|
|
|
|
|
|
|
Temperature |
|
Temperature Range |
-35°C to 400°C
(-30°F to 400°F) |
|
Resolution |
0.1°C / 0.1°F |
|
Accuracy |
±(1% of rdg + 1°C)
0°C to 200°C
±(2% of rdg + 3°C) -35°C to -0°C
±(1% of rdg + 2°F) -4°F to 400°F
±(2% of rdg + 4°F) -30°F to -4°F |
|
Sensor Type |
Type 'K' thermocouple |
|
Overload Protection |
60V DC or 30V AC rms |
|
|
|
|
|
|
|
Continuity |
|
Range |
400Ω |
|
Resolution |
1Ω |
|
Audible Indication |
Less than 25Ω |
|
Response Time |
500 msec |
|
Overload Protection |
500V DC or AC rms |
|
|
|
|
|
|
|
Non-Contact Voltage
Indicator |
|
VoltTect Non-Contact Voltage
Indicator |
Sense voltage 70V to 600V AC (50/60Hz)
beeper chirps and big bright red LED comes on, works when meter
setting is on any range. |
|
|
|
| |
|
|
General Specifications |
|
Jaw
opening/Conductor size |
30mm (1.18") |
|
Display |
3-3/4 digit Liquid Crystal Display
(LCD) maximum reading 3999 |
|
Measurement Update Rate |
2 times/second |
|
Polarity |
Automatic, positive implied, negative
polarity indication. |
|
Overrange |
(OL) or (-OL) is displayed |
|
Zero |
Automatic |
|
Display Hold |
Freeze the latest reading on the display |
|
Auto Power Off |
Approx. 10 minutes |
|
Operating
Temperature |
0°C
to 50°C (32°F to
122°F) at < 70% R.H. |
|
Storage
Temperature |
-20°C
to 60°C, (-4°F to
140°F) <80% R.H. (with battery
removed) |
|
Accuracy |
Stated accuracy at 74°F
±8°F, <75% R.H. |
|
Temperature
Coefficient |
0.1 x (specified accuracy) per
°F, (32°F to 66°F, 82°F to 122°F) |
|
Altitude |
2000 meters |
|
Safety |
Designed to meet IEC 61010-1, and IEC
61010-2-032,
CAT III 600 Volts class II and pollution degree 2, indoor use;
comply with CE, UL. |
|
Power Supply |
Two 1.5V size 'AAA'
(NEDA 24G or IEC R03) batteries |
|
Low Battery |
Yes |
|
Battery Life |
150 hours typical with carbon-zinc. 300
hours typical with alkaline. |
|
Size |
306mm (L) x 135mm (W)
x 30mm (D) |
|
Weight |
157g approx. |
| |
|
|
Included Accessories |
|
Supplied with: Test leads,
Batteries, User's Manual, Type 'K' Thermocouple and Carrying
Case. |
|
|
|
|