| Specifications |
|
AC Voltage Ranges |
400.0mV, 4.000V,
40.00V, 400.0V, 600V |
|
AC Voltage
Accuracy (4V to 400V range) |
±(1.5% of Rdg + 4 digits) (50 to 500Hz) |
|
|
|
|
AC Current Ranges |
400.0A, 800A |
|
AC Current
Accuracy (0 to 600A range) |
±(1.5% of Rdg + 5 digits) (40 to 100Hz) |
|
|
|
|
DC Voltage Ranges |
400.0mV, 4.000V,
40.00V, 400.0V, 600V |
|
DC Voltage
Accuracy (4V to 400V ranges) |
±(0.5% of Rdg + 3 digits) |
|
|
|
|
DC Current Ranges |
400.0A, 1000A |
|
DC Current
Accuracy (0 to 800A range) |
±(1.5% of Rdg + 4 digits) |
|
|
|
|
Resistance Ranges |
400.0Ω,
4.000Ω, 40.00Ω, 400.0kΩ, 40.00MΩ |
|
Resistance
Accuracy (4 to 400kΩ range) |
±(0.6% of Rdg + 4 digits) |
|
|
|
|
Capacitance Ranges |
500.0nF, 5.000µF,
50.00µF, 500.0µF,
3000µF |
|
Capacitance
Accuracy |
±(3.5% of Rdg + 6 digits) |
| |
|
| |
|
| General Specifications |
|
Display |
3-3/4 digits
4000-count LCD display |
|
Refresh Rate |
3 per second nominal |
|
Polarity |
Automatic |
|
Low Battery |
Below 2.4 volts
approx. |
|
Operating
Temperature |
0°C
to 40°C |
|
Relative Humidity |
Max R.H. 80% for
temperature up to 31°C decreasing |
|
|
linearly to 50% R.H.
at 40°C |
|
Storage
Temperature |
-20°C
to 60°C, <80% R.H. (with battery
removed) |
|
Temperature
Coefficient |
Nominal 0.15 x
(specified accuracy)/°C at |
|
|
(0°C
to 18°C or 28°C
to 40°C), or otherwise specified |
|
Sensing |
Average sensing |
|
Safety |
Meets EN61010-1:
2001; IEC61010-2-032 (2002), |
|
|
EN61010-2-032 (2002),
UL61010B-2-032 (2003), |
|
|
CAT III 600 Volts
AC/DC |
|
Transient
Protection |
6.5kV (1.2/50µs
surge) |
|
Pollution Degree |
2 |
|
EMC |
Meets EN61326-1 |
|
Power Supply |
Two 1.5V size 'AAA'
(NEDA 24G or IEC R03) batteries |
|
Power Consumption |
Typical 11mA for AC
amps/DC amps and 2.9mA all |
|
|
other functions |
|
Jaw
opening/Conductor size |
50mm maximum |
|
Size |
227mm (L) x 78mm (W)
x 40mm (D) |
|
Weight |
290g approx. |
| |
|
| |
|
|
Included Accessories |
|
Test Leads, Batteries
(installed), Users Manual, and Carrying Case |
| |