Model ACDC-34001IND
Industrial TRMS Clamp Meter
 
Amprobe Model ACDC-3400IND CAT IV Industrial TRMS Clamp Meter. (Meter shown with Optional TL-1500 Test Lead with set of Alligator clips

 

Features
  • TRMS Measurement.
  • AC Voltages to 750 Volts.
  • DC Voltages to 1000 Volts.
  • AC/DC Current to 1000 Amps.
  • Peak Hold.
  • Relative Zero.
  • Audible Continuity.
  • Auto and Manual ranging.
  • Auto Power OFF.
  • Data Hold.
  • Liquid Crystal Display (LCD) 6600 count with a 66-segment analog bar-graph and Backlight.
  • Diode Test.
  • Duty Cycle.
  • Accommodates conductors up to 51mm (2-ins) in diameter.
  • Safety CAT IV 600 Volt, CAT III 1000 Volt.
  • Accessories included with instrument: Test Leads, 9-volt battery (installed), Carrying Case and User's manual.
  • Optional Accessory: TL-1500 Test Lead with Alligator Clips

 

Specifications (valid for 23°C ±5°C, for less than 75% relative humidity)
DC Volts Range Accuracy
  660.0mV, 6.600V, 66.00V, 660.0V, 1000V ± (0.5% of rdg + 2 dgts)
Input Impedance 660mV: >100MΩ; 6.600V: 10MΩ;  
  66.00V to 1000V: 9.1MΩ  
Overload Protection 1000V DC or 750V AC rms  
       
AC Volts True RMS Range Frequency Accuracy
  660.0mV 50Hz to 100Hz ± (1.5% of rdg + 8 dgts)
  6.600V, 66.00V 50Hz to 100Hz ± (1.5% of rdg + 8 dgts)
  660.0V, 750V 50Hz to 100Hz ± (1.5% of rdg + 8 dgts)
Frequency 10% to 100% of voltage range 50Hz to 1kHz ± (0.1% of rdg + 5 dgts)
Peak Hold 66.00V, 660.0V, 750V 50Hz to 500Hz ± (3.0% of rdg + 300 dgts)
AC Coupled TRMS 5% to 100% of range    
Crest Factor ≤ 3    
Input Impedance 660mV: >100MΩ; 6.600V: 10MΩ; 66.00V to 1000V: 9.1MΩ
Overload Protection 1000V DC or 750V AC rms  
       
AC Current True RMS Range Frequency Accuracy
  660.0A 50Hz to 60Hz ± (2.0% of rdg + 10 dgts)
  660.0A 61Hz to 400Hz ± (3.0% of rdg + 10 dgts)
  1000A 50Hz to 60Hz ± (2.5% of rdg + 10 dgts)
  1000A 61Hz to 400Hz ± (3.5% of rdg + 10 dgts)
Frequency 10% to 100% of current range 50Hz to 1kHz ± (0.1% of rdg + 5 dgts)
Peak Hold 660.0A, 1000A 50Hz to 400Hz ± (3.0% of rdg + 200 dgts)
AC Coupled TRMS 5% to 100% of range    
Crest Factor ≤ 3    
Overload Protection 1000A AC    
       
DC Current Range Accuracy  
  660.0A ± (2.0% of rdg + 5 dgts)
  1000A ± (3.0% of rdg + 5 dgts)
Overload Protection 1000A DC    
       
Resistance Range Accuracy  
  660.0Ω, 6.600kΩ, ± (1.0% of rdg + 5 dgts)
  66.00kΩ, 660.0kΩ  
  6.600MΩ ± (2.0% of rdg + 5 dgts)
  66.00MΩ ± (3.5% of rdg + 5 dgts)
Open Circuit Volts -0.8V DC typical, (-1.2V DC on 660.0Ω range)
Overvoltage Protection 1000V DC or 750V AC rms  
       
Capacitance Range Accuracy  
  6.600nF, 66.00nF, ± (3.0% of rdg + 20 dgts)
  660.0nF, 6.600µF, 66.00µF, ± (3.0% of rdg + 10 dgts)
  660.0µF    
  6.6mF ± (5.0% of rdg + 10 dgts)
Overload Protection 1000V DC or 750V AC rms    
       
Frequency Range   Accuracy
(Auto Ranging) 66.00Hz, 660.0Hz, 6.600KHz, 66.00KHz, 660.0KHz ± (0.1% of rdg + 3 dgts)
  1.000MHz    
Sensitivity 10Hz to 1MHz: > 3.5V rms    
Minimum Pulse Width      
       
Diode Test      
Test Current 1.0mA approx.    
Accuracy ± (1.5% of rdg + 5 dgts)    
Open Circuit Volts 3.2V DC typical    
Audible Indication < 0.25V    
Overload Protection 1000V DC or 750V AC rms    
       
Continuity      
Ranges 660.0Ω    
Audible Indication < 30Ω    
Response Time 500ms    
Overload Protection 1000V DC or 750V AC rms    
       
% Duty Cycle      
Range 5.0% to 95.0%    
Resolution 0.1%    
Minimum Pulse Width > 10µs    
Frequency Range 40Hz to 20kHz    
Accuracy (5V logic) ± (2.0% of rdg + 10 dgts)    
Overload Protection 1000V DC or 750V AC rms    
       
       
General Specifications
Jaw Opening 57mm (2 inches)
Display 3-3/4 digit LCD (6600 count) with a 66- segment analog bar graph
Polarity Automatic, positive implied, negative polarity indication
Overrange 'OL' or '-OL'
Zero Automatic
Low Battery Indication Yes
Auto Power OFF Yes
Backlight Auto-off approx. 60 seconds
Measurement Rate 2.8 times a second nominal
Analog Bar-Graph 28 times a second
   
Operating Temperature 0°C to 50°C (32°F to 122°F) <70% R.H.
Storage Temperature -20°C to 60°C (-4°F to 140°F) <80% R.H. with battery removed from meter
Temperature Coefficient 0.1 x (specified accuracy) per °C. (0°C to 18°C. 28°C to 50°C)
Altitude 2000 meters. (indoor use)
   
Power Single standard 9-volt battery, NEDA 1604, JIS 006p, IEC 6F22
Battery Life Typically 75 hours with carbon-sinc; 150 hours with Alkaline
Dimensions 283mm (L) x 105mm (W) x 50mm (D)
Weight 559gm
Safety LVD Meets EN 61010-1:2001 and EN 61010-2-032:2002, CAT III 1000V,
  CAT IV 600V, class II and pollution degree 2
CE EN 61326-1:2006
       
   
Included Accessories
Set of Test Leads, battery installed, Users Manual and Carrying Case

 

AEMC | AMPROBE | CIE | FLUKE | HT ITALIA | HODEN | PROVA | POMONA | RAYTECH |  SILVERTRONIC
Home | PRODUCTS | SEARCH
Obiat Pty. Ltd.
A.C.N. 003 166 952      A.B.N. 23 003 166 952
Unit 9A/8 Avenue of the Americas, Newington NSW 2127 Australia
P.O. Box 6901 Silverwater  NSW Australia 1811

Phone: 61-2-9748- 8699

Fax: 61-2-9748-8544

E-mail:
 

 information@obiat.com.au
sales@obiat.com.au

Copyright ©                                             Last Update: Saturday, 21 May 2011