| Specifications |
|
AC Voltage Ranges
(45 to 300Hz) |
500.00mV,
5.0000/50.000V/500.00/1000.0V |
|
AC Voltage
Accuracy |
±(0.8% of Rdg + 20 digits) 45Hz to 300Hz |
|
AC Current Ranges
(50 to 60Hz |
500.00/5000.0µA,
50.000/500.00mA, 5.0000/10.000A |
|
AC Current
Accuracy |
±(0.5% of Rdg + 50 digits) |
|
|
|
|
DC Voltage Ranges |
500.00mV,
5.0000/50.000V, 500.00/1000.0V |
|
DC Voltage
Accuracy |
±(0.02% of Rdg + 2 digits) |
|
DC Current Ranges |
500.00/5000.0µA,
50.000/500.00mA, 5.0000/10.000A |
|
DC Current
Accuracy |
±(0.5% of Rdg + 20 digits) |
|
|
|
|
Resistance Ranges |
500.00Ω,
5.0000/50.000Ω/500.00k, 5.0000/50.000MΩ |
|
Resistance
Accuracy |
±(0.10% of Rdg + 6 digits) for 500Ω to
500kΩ range |
|
|
|
|
Frequency Ranges |
5.0000Hz to
200.000kHz |
|
Accuracy |
±(0.002% of Rdg + 4 digits) |
|
|
|
|
Capacitance Ranges |
50.00/500.0nF,
5.000/50.00/500.0/9999µF |
|
Accuracy |
±(2.0% of Rdg + 3 digits) for 50nF to 50µF
range |
|
|
|
|
Duty Cycle |
0.1% to 99.99%
±(3 digits/kHz + 2 digits) |
|
|
|
|
Temperature Range |
-50°C to 1000°C |
|
Accuracy |
±(0.3% of Rdg + 1°C) |
|
|
|
|
Diode Range |
5.0000V |
|
Accuracy |
1% + 1 digit |
|
Test Current |
0.4mA typical |
|
Open Circuit Voltage |
< 3.5V DC |
| |
|
| |
|
|
Environmental |
|
Operating
Temperature |
0°C
to 45°C |
|
Storage
Temperature |
-20°C
to 60°C <80% R.H. (with battery removed) |
|
Relative Humidity |
Max. R.H. 80% for
temperature up to 31°C decreasing
linearly |
|
|
to 50% R.H. at 45°C |
|
Pollution Degree |
2 |
| |
|
| |
|
|
Safety Conformity |
|
Safety |
Double insulated per IEC 61010-1 2nd
edition, UL 61010-1 2nd edition |
|
|
and Can/CSA C22.2 No. 61010-1-0. 92 to
category III 1000V AC/DC, |
|
|
and category IV 600V AC/DC |
|
Terminals/Measurement Category |
Voltage: CAT III 1000V AC/DC, and CAT IV
600V AC/DC |
|
|
Current (µA, mA,
A): CAT III and CAT IV 600V AC and 300V DC |
|
Overload Protection |
µA and mA: 1A/600V,
IR 10kA or better, Fuse |
|
|
Amps: 10A/600V, IR 100kA or better, Fuse |
|
|
Volts: 1050V rms, 1450V peak |
|
|
Milli-Volts and Others: 600V DC and AC
rms |
|
Transient Protection |
8KV (1.2/50µS
Surge) |
|
E.M.C. |
Meets EN 61326-1:2006 (EN 55022), EN
61000-3-2, EN 61000-3-3, |
|
|
EN 61000-4-2, EN61000-4-3, EN 61000-4-4,
EN 61000-4-5, |
|
|
EN 61000-4-6, EN 61000-4-8, EN
61000-4-11) |
| |
|
| |
|
|
General Specifications |
|
Display |
4-4/5 digits 50,000
counts. Selectable stable mode, |
|
|
5-4/5 digits 500,000
counts for DC Voltage and 6 digits 999,999 counts |
|
|
for Frequency (Hz) |
|
Polarity |
Automatic |
|
Display Refresh
Rate |
4-4/5 digits fast
mode 5 per second nominal |
|
|
5-4/5 digits stable
mode 1.25 per second nominal |
|
|
42 Segments Bar Graph
60 per second max. |
|
Sensing |
AC, AC+DC True RMS |
|
Power Supply |
Single Alkaline 9
volt battery NEDA 1604A, JIS 6AM6 or IEC 6LF22 |
|
Power Consumption |
6mA typical |
|
Low Battery |
Below 7 volts approx. |
|
APO Timing |
Idle for 17 minutes |
|
APO Consumption |
30µA typical |
|
|
|
|
Dimensions |
317.6mm (L) x 177.8mm (W)
x 76.2mm (D) |
|
Weight |
635g |
| |
|
|
Included Accessories |
|
Thermocouple, Battery (installed),
Test Leads and User Manual |
| |
| |
|
|
Optional Accessories |
|
USB-KIT3 |
PC Interface Kit (PC connection cable
with Software) |
|
www.amprobe.com |
Software |
|
CC-ACDC |
Carrying Case |
| |
|