| Specifications (23°C
±5°C,
80% R.H. ; Maximum input, all functions/ranges: 600VDC or ACrms) |
|
DC Voltage Range |
340mV, 3.400V, 340V,
600V |
|
DC Voltage
Accuracy |
±(1.0% of Rdg + 2 digits) for 3.400V range |
|
|
±(2.0% of Rdg + 2 digits) for all other ranges |
|
DC Voltage
Resolution |
100μV
in 340mV range |
|
Input Impedance |
>100MΩ
(340mV range), 10MΩ (3.4V range), 9.1MΩ all other ranges |
|
|
|
|
AC Voltage Ranges
(50/60Hz) |
3.400V, 34.00V, 340V,
600V |
|
AC Voltage
Accuracy |
±(4.0% of Rdg + 5 digits) |
|
AC Voltage
Resolution (3.4V range) |
1mV |
|
Input Impedance |
10MΩ (3.4V range), 9.1MΩ all other ranges |
|
|
|
|
Resistance |
340Ω,
3.400kΩ, 34.00kΩ, 340.0kΩ, 3.400MΩ, 34MΩ |
|
Resolution
|
100mΩ
(in 340Ω range) |
|
Accuracy (340Ω,
3.4kΩ, 34kΩ, 340kΩ range) |
±(2.0% of Rdg + 4 digits)
|
|
Accuracy (3.4MΩ
range) |
±(3.0% of Rdg + 4 digits) |
|
Accuracy (34MΩ
range) |
±(5.0% of Rdg + 5 digits) |
|
Test Voltage |
-0.45V DC typical,
(-1.2V DC on 340Ω range) |
|
|
|
|
Diode Test Range |
3.4V |
|
Accuracy |
±(3.0% of Rdg + 3 digits) |
|
Test Current |
0.6mA (Vf=0.6V) |
|
|
|
|
Continuity Check
Range |
340Ω |
|
Indication |
at approx. R <35Ω |
|
Test Current |
0.7mA |
| |
|
| General Specifications |
|
Display |
3-3/4 digits LCD,
maximum reading 3400-counts |
|
Display Refresh
Rate |
2 per second (20 per
second for Bar Graph) |
|
Range Selection |
Auto-ranging and
manual range lock |
|
Overrange
Indication |
'OL' |
|
Polarity
Indication |
- is displayed (+ is
implied) |
|
Battery Warning |
Yes (when <1.25V
±0.1V) |
|
Operating
Temperature |
0°C
to 40°C (32°F
to 104°F), <70% R.H. non-condensing |
|
Storage
Temperature |
-20°C
to 60°C (-4°F
to 140°F), <80% R.H. non-condensing |
|
Power Supply |
Two 1.5V batteries
(L1154F or LR-44) |
|
Battery Life |
70 hours continuous
operation |
|
Continuity Test |
Beeper alert |
|
Auto Off |
After 10 minutes of
non-use |
|
Dimensions |
130mm (L) x 77mm (W)
x 18mm (D) |
|
|
5.1" (L) x 3.1" (W) x
0.6" (D) |
|
Weight |
110g (3.9oz)
including battery |
| |
|
|
Included Accessories |
|
Test leads, Batteries (installed),
pocket carrying case and User manual. |
|
| |
|