| The ultimate component checker
measures Inductance, Capacitance, Resistance, Transistors, Diodes
and Microwave diodes. |
 |
Features
- Plug-in test slots and test leads with threaded alligator
clips
- Oversized, digital display
- Data Hold and Max Hold
- "Zero Adjust" Pot for Ohms
- Low Battery Indication
- Auto-Power Off
 |
|
| Specifications (23°C
± 5°C, <75% R.H. non-condensing) |
|
Resistance:
|
|
Function |
Range |
Accuracy |
|
Measurement |
20Ω |
± 1.2% of Rdg (zero
adjust) |
|
200Ω |
±(0.5% of Rdg + 3
digits) |
|
2kΩ to 2MΩ |
±(0.5% of Rdg + 1
digit) |
|
20MΩ |
±(2.0% of Rdg + 2
digits) |
|
Resolution |
10mΩ in 20Ω range |
|
|
Open Circuit Voltage |
20Ω range |
6.5V DC |
|
200Ω range |
3.0V DC |
|
All other ranges |
1.2V DC |
|
| |
|
Continuity: |
|
Audible Indication |
2kΩ range |
Tone at R<30Ω |
|
Response Time |
800mS approx. |
|
|
| |
|
Diode Test: |
|
Test Current |
1mA (approximately) |
|
|
Test Voltage |
3.0V DC |
±(1.5% of Rdg + 1
digit) |
|
Display |
Forward junction voltage |
|
|
| |
|
Microwave Diode Test: |
|
Test Current |
0.6mA (approximately) |
|
|
Test Voltage |
7.0V DC (typical) |
±(3.0% of Rdg + 1
digit) |
|
Display |
Forward junction voltage |
|
|
| |
|
Capacitance: |
|
Function |
Range |
Accuracy |
|
Measurement
|
200pF to 200nF |
±(1.0% of Rdg + 1
digit) |
|
2µF to 200µF |
±(2.0% of Rdg + 1
digit) |
|
200µF to 1000µF |
±(3.0% of Rdg + 3
digits) |
|
1000µF to 2000µF |
±(5.0% of Rdg + 5
digits) |
|
|
Note: in lower ranges,
subtract 6 points residual offset reading from result |
| |
|
Test Frequency |
200pF to 2µF |
1000Hz |
|
20µF to 200µF |
100Hz |
|
2000µF |
10Hz |
|
Temperature Coefficient |
<0.5µF |
0.1%/°C |
|
|
>0.5µF |
0.2%/°C |
|
| |
|
Inductance: |
|
Function |
Range |
Accuracy |
|
Measurement |
200µH |
±(5.0% of Rdg + 30
digits)* |
|
2 to 200mH |
±(3.0% of Rdg + 20
digits)* |
|
2mH to 200H |
±(5.0% of Rdg + 20
digits)* |
|
| Note* For values of Q
≤ 7 |
| |
| |
|
Test Frequency |
200µH to 2H range |
1000Hz |
|
20H to 200H range |
100Hz |
|
Temperature Coefficient |
<0.5H |
0.2%/°C |
|
>0.5H |
0.5%/°C |
|
| |
|
Transistor Test: |
|
hFE Range |
0 to 1000 |
|
hFE Base Current |
3µA approx. |
|
hFE Voltage C-E |
3.0V DC approx. |
|
Iceo Range, Leakage Current |
10nA to 20µA |
|
| |
|
Overload Protection: |
|
Resistance |
350V DC or AC RMS |
|
Capacitance |
0.1A/250V fast acting fuse |
|
Continuity |
350V DC or AC RMS |
|
Diode Test |
350V DC or AC RMS |
|
Micro Wave Diode Test |
350V DC or AC RMS |
|
Inductance |
0.1A/250V fast acting fuse |
|
| |
|
General Specifications |
|
Display |
3-1/2 digit (LCD), maximum reading of 1999 |
|
Display Update Rate |
2.5/sec, nominal |
|
Power Supply |
9 Volt Alkaline battery |
|
Battery Life |
200-hours |
|
Operating Temperature |
-20°C to 50°C (32°F
to 122°F), <70% R.H. |
|
Storage Temperature |
-20°C to 60°C (-4°F
to 140°F), <80% R.H. battery removed |
|
Dimensions
|
183mm (L) x 79mm (W) x 38mm (D)
7.2" (L) x 3.1" (W) x 1.5" (D) |
|
Weight |
311 gms (11 oz) including battery |
|
Warranty |
One-year |
|
| |
|
Included Accessories |
|
Test leads, alligator clips,
battery (installed), spare fuse and user's manual. |
|
| |