Obiat Pty Ltd distributors of Electronic and Professional Scientific Test Equipment.

 

Sydney Australia

. . . . keeping your world up and running

Navigation: Amprobe Electrical Testers > Model PK-100R
Amprobe Test Instruments Logo

Amprobe Electrical Testers

Model PK-100R Electrical Test Kit
 

Complete kit to check for voltage in receptacles, electrical circuits, fuses, light bulbs and electrical connections.
 

Model PK-100R Electrical Test Kit Features
  • VT201A Non contact Voltage Detector.
  • Quickly checks outlets, switches or extension cords for voltage.
  • PM-60 Digital Multimeter.
  • Measures AC/DC voltage of outlets, switches, extension cords or household batteries.
  • Continuity function checks light bulbs and fuses.
  • Resistance, Capacitance and Frequency to perform more advanced repairs of appliances or HVAC systems.
  • ST102A Polarity Cube.
  • Trouble shoots 120V AC grounded outlets and checks GFCI receptacles and breakers.

 

Measurement

Range

Resolution

Accuracy

AC Volts

400.0mV

0.1mV

±(1.5% of Rdg + 5 digits)

 

4.000V

0.001V

±(0.9% of Rdg + 5 digits)

 

40.00V

0.01V

±(0.9% of Rdg + 5 digits)

 

400.0V

0.1V

±(0.9% of Rdg + 5 digits)

 

600V

1V

±(0.9% of Rdg + 5 digits)

Frequency Response

50Hz to 500Hz

AC Conversion Type

AC Coupled Average Sensing, RMS Indication

Input Impedance

10MΩ, <100pF

Overload Protection

600V rms

 
 

Measurement

Range

Resolution

Accuracy

DC Volts

400.0mV

0.1mV

±(0.7% of Rdg + 5 digits)

 

4.000V

0.001V

±(0.6% of Rdg + 5 digits)

 

40.00V

0.01V

±(0.6% of Rdg + 5 digits)

 

400.0V

0.1V

±(0.6% of Rdg + 5 digits)

 

600V

1V

±(0.7% of Rdg + 5 digits)

Input Impedance

10MΩ, <100pF

Overload Protection

600V rms

 
 

Measurement

Range

Resolution

Accuracy

Ohms

400.0Ω

0.1Ω

±(0.9% of Rdg + 5 digits)

 

4.000KΩ

0.001KΩ

±(0.9% of Rdg + 2 digits)

 

40.00KΩ

0.01KΩ

±(0.9% of Rdg + 2 digits)

 

400.0KΩ

0.1KΩ

±(1.5% of Rdg + 2 digits)

 

4.000MΩ

0.001MΩ

±(1.5% of Rdg + 5 digits)

 

40.00MΩ

0.01MΩ

±(1.5% of Rdg + 5 digits)

Open Circuit Voltage

0.4V there is a little rolling less than ±2%

Overload Protection

600V rms

Continuity Threshold

less than 50Ω approx.

Continuity Indicator

2.7KHz Tone Buzzer

Input Protection

600V rms

 
 

Measurement

Range

Resolution

Accuracy

Capacitance

40.00nF

0.01nF

±(5% of Rdg + 0.4nF)

 

400.0nF

0.1nF

±(2.9% of Rdg + 5 digits)

 

4.000µF

0.001µF

±(2.9% of Rdg + 5 digits)

 

40.00µF

0.01µF

±(2.9% of Rdg + 5 digits)

 

400.0µF

0.1µF

±(2.9% of Rdg + 5 digits)

Measuring Time

<30 sec. (400.0µF range), <10 sec. (40.0µF range), <3 sec. (other ranges)

Overload Protection

600V rms

 
 

Measurement

Range

Resolution

Accuracy

Frequency

40.00Hz

0.01Hz

±(0.3% of Rdg + 5 digits)

 

400.0Hz

0.1Hz

±(0.3% of Rdg + 5 digits)

 

4.000Hz

0.001KHz

±(0.3% of Rdg + 5 digits)

 

40.00Hz

0.01KHz

±(0.3% of Rdg + 5 digits)

Sensitivity

>10Vp-p (40KHz range)
>1.5Vp-p (other ranges)

Max. Sensitivity

600V rms

Overload Protection

600V rms

 
 

Measurement

Range

Resolution

Accuracy

%

0.1% to 99.9%

0.1%

±(0.5% of Rdg + 10 digits)

Sensitivity

1.5Vp-p

Overload Protection

600V rms

 
 

Measurement

Range

Resolution

Accuracy

AC Current

40.0µA

0.1µA

±(1.5% of Rdg + 5 digits)

 

4.000mA

0.001mA

±(1.5% of Rdg + 5 digits)

Frequency Response

50Hz to 500Hz

AC Conversion Type

AC Coupled Average Sensing, RMS Indication

Input Impedance

3KΩ approx.

Overload Protection

600V rms

 
 

Diode Test

 

Test Current

350µA typical

Open Circuit Voltage

1.8V DC maximum

Overload Protection

600V rms

 
 

Specifications

LCD Display

4000 count digit large scale LCD readout

Measuring Rate

3 times/second

Polarity Indication

Automatic, positive implied

Overrange Indication

'OL' or '-OL' unit symbol indication

Auto Power Off

approx. 20 minutes after power ON.

Low Battery Indication

Yes

Power Requirement

2 x 1.5Volt batteries

Battery Life

50 hours approx.

Shock/Vibration

Sinusoidal vibration per MIL-T-28800E (5Hz to 55Hz, 3g/0.007lb max.)

Drop Protection

1 meter drop approx.

Overvoltage Category

IEC 61010-1 300V CAT III, 600V CAT II

Operating Altitude

2000 meters

Pollution Degree

2

EMC

EN 61326-1

 
 

General Specification

Operating Temperature

0°C to 30°C, (≤80% R.H.)

Storage Temperature

-10°C to 60°C (0 to 80% R.H.) (batteries not fitted)

Dimensions

112mm (L) x 56mm (W) x 12mm (D)

Weight

115 gms

 
 
AEMC | AMPROBE | CIE | FLUKE | HT ITALIA | HODEN | PROVA | POMONA | RAYTECH |  SILVERTRONIC
Home | PRODUCTS | SEARCH
Obiat Pty. Ltd.
A.C.N. 003 166 952      A.B.N. 23 003 166 952