| Specifications |
|
DC Voltage Ranges |
400mV, 4.000V, 40.00V, 400V, 600V |
|
DC Voltage Accuracy |
±(1.0% of Rdg + 2 digits) for 400mV range |
| |
±(2.0% of Rdg + 2 digits) for 4V to 400V ranges |
| |
±(2.5% of Rdg + 4 digits) for 600V range |
|
NMRR |
>50dB @ 50/60Hz |
|
CMRR |
>120dB @ DC, 50/60Hz;
Rs=1kΩ |
|
Input Impedance |
10MΩ, 30pF nominal; (1000MW for
400.0mV range) |
| |
|
|
AC Voltage Ranges |
4.000V, 40.00V, 400V, 600V |
|
AC Voltage Accuracy (50/60Hz) |
±(2.0% of Rdg + 5 digits) for 4V to 400V ranges |
|
AC Voltage Accuracy (50/500Hz) |
±(3.0% of Rdg + 5 digits) for 4V to 400V ranges |
|
AC Voltage Accuracy (50/500Hz) |
±(3.5% of Rdg + 5 digits) for 600V range |
|
CMRR |
>60dB @ DC to 60Hz, Rs=1kΩ |
|
Input Impedance |
10MΩ, 30pF nominal |
| |
|
|
Capacitance Ranges |
500nF, 5.000μF, 50.00μF,
500.0μF, 3000μF |
|
Capacitance Accuracy |
±(3.5% of Rdg + 6 digits4) for 500.0μF,
3000μF1,3 |
|
Note 1. Additional 50.00nF range accuracy not specified.
Note 2. Accuracies with film capacitor or better.
Note 3. Updates >1 minute on large values.
Note 4. Specified with battery voltage above 2.8V (half full
battery). Accuracy decreases gradually to 12% at low battery warning
voltage of approx. 2.4V.
|
| |
|
|
Resistance Ranges |
400.0Ω, 4.000kΩ, 40.00kΩ,
400.0kΩ, 4.000MΩ, 40.00MΩ |
|
Accuracy |
±(1.5% of Rdg + 6 digits) for 400.0Ω
range |
| |
±(1.0% of Rdg + 4 digits) for 4.000kΩ,
40.00kΩ, 400.0kΩ ranges |
| |
±(1.5% of Rdg + 4 digits) for 4.000MΩ |
| |
±(2.5% of Rdg + 4 digits) for 40.00MΩ |
|
Open Circuit Voltage |
0.4V DC typical |
| |
|
|
Frequency Ranges |
400Hz, 4kHz, 40kHz, 400kHz, 1MHz |
|
Frequency Accuracy |
±(0.5% of Rdg + 4 digits) for 400Hz, 4kHz, 40kHz, 400kHz,
1MHz1 |
|
Sensitivity (V-peak) (5Hz to 100kHz) |
>1.3Vp |
|
(100kHz to 500kHz) |
>2.2Vp |
|
(500kHz to 1MHz) |
>4.2Vp |
|
Note 1. Specified at input voltage <20V AC rms input signal:
Sine-wave, or square-wave with duty cycle >40% and <70% Sensitivity
(V-peak)
|
| |
|
|
Diode Test Current |
0.25mA typical |
|
Open Circuit Voltage |
1.6V DC |
| |
|
|
Continuity Tester Open Circuit Voltage |
0.4V DC typical |
|
Audible Threshold |
65Ω
±55Ω |
| |
|
| General Specifications |
|
Display and Update Rate |
3-3/4 digits 4000-counts; Updates 3 per second
nominal |
|
Sensing |
Average sensing |
|
Operating Temperature |
0°C to 40°C |
|
Storage Temperature |
-20°C to 60°C,
<80% R.H. (with battery removed) |
|
Overload Protection |
600V DC and 600V AC rms |
|
Low Battery |
Below 2.4V |
|
Power Supply |
One 3V button battery (IEC-CR2032; ANSI-NEDA-5004LC) |
|
Power Consumption |
2mA typical |
|
Dimensions |
113mm (L) x 53mm (W) x 10.2mm (D)
4.4" (L) x 2.1" (W) x 0.4" (D) |
|
Weight |
78g (3oz) |
| |
|
|
Included Accessories |
|
Test leads and Battery
(installed), user manual |
|