Perform precision temperature and humidity measurement for HVAC, Indoor Air Quality and environmental applications. The large LCD display, full suite of measuring features and two temperature probes (internal and external) make this product a preferred choice for a professional.

Amprobe Model THWD-10W Relative Humidity Meter with Wireless

Features
  • Wireless (two way transmission).
  • Highly stable humidity measurement ±2.5%.
  • Processing relative humidity and temperature measurements simultaneously.
  • Two temperature sensors (internal and external).
  • Wet/Dry Bulb, Dew Point measurements.
  • Easy selection between K / NTC / K-DP.
  • Min/Max/Average/Relative/Hold functions.
  • Includes: Four (4) 1.5V batteries, Type 'K' thermocouple and users manual.

Safety Conformity

 

Electrical Specification

Temperature Scale

Celsius or Fahrenheit user-selectable

Measurement Range

Type 'K' thermocouple -50°C to 1000°C, (-50°F to 1832°F)

Resolution

0.1°C or 0.2°F

Accuracy

Accuracy is specified for operating temperatures over the range 18°C to 28°C (64°F to 82°F), for 1-year, not including thermocouple error.
±(0.1% of rdg + 1°C) on -50°C to 1000°C ±(0.1% of rdg + 2°F) on
-50°F to 1832°F ±(0.05% of rdg + 1.4°F) -58°F to -328°F

Sensor (internal)

Thermistor temperature sensor

Range

0°C to 60°C, (32°F to 140°F)

Resolution

0.1°C or 0.2°F

Accuracy

±2°C on 0°C to 10°C / ±0.5°C on 10°C to 45°C / ±2°C on 45°C to 60°C /
±4°F on 32°F to 50°F / ±1°F on 50°F to 113°F / ±4°F on 113°F to 140°F

 
 

Relative Humidity Specification

Sensor

Capacitive Humidity Sensor

Range

0% to 100% R.H.

Accuracy

±2.5% at 25°C (77°F), 10% to 90% R.H.
±5% at 25°C (77°F), 0% to 10% R.H., 90% to 100% R.H.

Sensor Response Time

60 seconds typical (for 90% of Total Range)

Sensor Hysteresis

±1% R.H. typical (excursion of 10% to 90% to 10% R.H.)

Temperature

0.1 times the applicable accuracy

Coefficient

specification per °C from 0°C to 18°C and 18°C to 50°C;
(32°F to 64°F and 82°F to 122°F)

Input Protection

Maximum input Voltage on any combination of input connections (24 Volts DC or 24 Volts AC Rms)

Input Connector

Accepts standard miniature thermocouple connectors (flat blades spaced 7.9mm, center to center)

 
 

General Specification

Display

5-digit Liquid Crystal Display (LCD)

Polarity

Automatic, positive implied, negative polarity indication

Operating Temperature

0°C to 50°C

Storage Temperature

-20°C to 60°C, < 70% R.H. with battery removed from meter

Operating Humidity

< 80% R.H.

Accuracy

Stated accuracy at 23°C ±5°C, < 75% R.H.

Power Supply

4 x 1.5 Volt type 'AAA' (NEDA 24G or IEC R03) batteries

Battery Life

200 hours typical

Auto Power Off

Yes

Low Battery Indication

Yes

Dimension

241.3mm (L) x 157.98mm (W) x 76.2mm (D)

Weight

304gms including batteries

 
 

Wireless

Frequency Range 910MHz to 920MHz
Low current consumption less than 1mA.
Transmitting distance can reach 25 meters without magnetic interference.
 
 

Included Accessories

Includes Four (4) type 'AAA' 1.5V batteries (installed), Type 'K' thermocouple and users manual.

 
 
AEMC | AMPROBE | CIE | FLUKE | HT ITALIA | HODEN | PROVA | POMONA | RAYTECH |  SILVERTRONIC
Home | PRODUCTS | SEARCH
Obiat Pty. Ltd.
A.C.N. 003 166 952      A.B.N. 23 003 166 952
Unit 9A/8 Avenue of the Americas, Newington NSW 2127 Australia
P.O. Box 6901 Silverwater  NSW Australia 1811

Phone: 61-2-9748- 8699

Fax: 61-2-9748-8544

E-mail:
 

 information@obiat.com.au
sales@obiat.com.au

Copyright ©                                             Last Update: Saturday, 21 May 2011