Model TIC 300 PRO High Energy TIC Tracer -
Non Contact AC Voltage Detector |
| |
|
Rugged and reliable for utility, industrial
and mine safety applications, The TIC 300 PRO warns against
dangerous voltages in low and medium voltage applications up to 122
KV without contacting the energized conductor
|
|
|
 |
Features
- Utility tool for checking transmission lines, power
distribution equipment, down power lines, fuses and load break
connectors.
- Lower voltage setting for checking voltage presence in
breaker panels, breakers, power outlets and wiring.
- Verifies presence of Voltage from 30V AC to 122,000V AC
(122kV).
- Non-contact AC voltage detection.
- Visual and audible voltage indication.
- Self-test verifies that the tester is working correctly.
- Ergonomic design with a convenient handle.
- Drop-proof to 6 feet.
- Used with Hot Stick TIC 410A for voltage higher than 1500V
AC.

|
|
| |
| Specifications |
| Non-Contact Voltage Detection |
30V to 1500V AC |
| |
1500V to 122,000V AC (with Hot Stick TIC 410A) |
|
| OSHA listed clearance distances for working with voltage. National or
local requirements may be different. |
| |
| Line
Voltage (KV) |
Phase To
Ground |
Phase to
Phase |
| Phase to
Phase |
(ft-in) |
(m) |
(ft-in) |
)m) |
| 0.03 to 1.0 |
note 1 |
note 1 |
note 1 |
note 1 |
| 1.1 to 15.0 |
2-1 |
0.64 |
2-2 |
0.66 |
| 15.1 to 36.0 |
2-4 |
0.72 |
2-7 |
0.77 |
| 36.1 to 46.0 |
2-7 |
0.77 |
2-10 |
0.77 |
| 46.1 to 72.5 |
3-0 |
0.90 |
3-6 |
1.05 |
| 72.6 to 121 |
3-2 |
0.95 |
4-3 |
1.29 |
|
| |
| Note 1: No contact necessary |
| |
| Caution: If a three phase circuit is being checked and one phase is
open, the voltage from another |
phase maybe detected and will give a faulty indication. Always make
sure that the phase
cables are separated by at least 381mm (15 ins) |
| |
| |
|
Low Voltage |
High Voltage |
|
Phase to Ground |
Detection Range (Avg.) |
Phase to
Ground |
Detection Range (Avg.) |
|
30V |
2.7" |
1.5kV |
1' 2" |
|
75V |
9.7" |
2.0kV |
2' 5" |
|
100V |
1' 1" |
4.0kV |
4' 3" |
|
120V |
1' 6" |
10.0kV |
6' 3" |
|
220V |
2' 4" |
25.0kV |
9' 4" |
|
500V |
4' 2" |
50.0kV |
13' 0" |
|
1000V |
6' 3" |
75.0kV |
14' 8" |
|
1500V |
7' 9" |
100.0kV |
19' 8" |
| |
|
122.0kV |
22' 0" |
|
| |
| |
|
Specifications |
|
Operating Voltage Low Range |
30 Volts to 1500 Volts AC |
|
Operating Voltage High Range |
1500 Volts to 122,000 Volts (122KV) AC |
|
Power |
9 Volt Alkaline battery |
|
Power Consumption OFF |
OFF: 340µA |
|
Low Detection mode: 39mA |
|
High Detection mode: 39mA |
|
Duty Cycle |
Continuous |
|
Response Time |
Instantaneous |
|
Environment |
<2000 meters, outdoor operation |
|
| |
| |
|
General Specification |
|
Operating Temperature |
0°C to 52°C, ( R.H.
< 90%) |
|
Storage Temperature |
0°C to 52°C, (R.H.
< 90%), batteries removed |
|
Dimensions |
345mm (L) x 75mm (W) x 47mm (D) |
|
Weight |