Model TMD90A
Dual Input Digital Thermometer |
| |
Dual input,
wide measurement ranges
The TMD90A is a dual input thermometer that accepts type K,
J, T, R, S, and E thermocouples and
is ideal for HVAC/R technicians, electricians, research,
industrial process, and quality control. The dual inputs allow
easy super-heat and sub-cool temperature measurement as well as
cut-out and in temperature measurements. The triple display with
backlight shows T1, T2, and T1 - T2 and includes Hold, Min/Max,
Relative, and Timer / Date Stamp function
The TMD90A supports dual channel real time data acquisition using
the built-in RS-232 interface and optional software and data
transfer cable (Model TM-SWA).
|
 |
Features
- High accuracy, multiple type input thermometer.
- Displays T1, T2, and T1-T2 simultaneously.
- Accepts six different thermocouple types K, J, T, R, S E.
- Outputs real time measurement data with time stamp and Min/Max
indicators.
- Measures from -328°F / -200°C to 3200°F / 1760°C.
- Supplied with Deluxe carrying case and two Type K probes.
- RS232 output with optional cable and software, TM-SW.
 |
|
| |
| Temperature Ranges |
|
Thermocouple Type |
Range |
| |
Type K |
-200°C to 1370°C
|
-328°F to 2498°F |
| |
Type J |
-200°C to 760°C
|
-328°F to 1400°F |
| |
Type T |
-200°C to 390°C
|
-328°F to 730°F |
| |
Type R and S |
0°C to 1760°C
|
-32°F to 3200°F |
| |
Type E |
-200°C to 736°C
|
-328°F to 1832°F |
|
| |
| Temperature Accuracy °C |
|
T/C Type |
Range |
Resolution |
Accuracy |
| Type K |
-200°C to 650°C |
0.1° |
0.1% of Rdg +0.7°C |
| 651°C to 1370°C |
1.0° |
0.1% of Rdg +0.7°C |
| Type J |
-200°C to 500°C |
0.1° |
0.1% of Rdg +0.7°C |
| 501°C to 760°C |
1.0° |
0.1% of Rdg +0.7°C |
| Type T |
-200°C to 390°C |
0.1° |
0.1% of Rdg +0.7°C |
| Type R |
0°C to 1000°C |
0.1° |
0.3% of Rdg +0.7°C |
| 1001°C to 1760°C |
1.0° |
0.3% of Rdg +0.7°C |
| Type S |
0°C to 1000°C |
0.1° |
0.3% of Rdg +0.7°C |
| 1001°C to 1760°C |
1.0° |
0.3% of Rdg +0.7°C |
| Type E |
-200°C to 380°C |
0.1° |
0.3% of Rdg +0.7°C |
| -381°C to 736°C |
1.0° |
0.3% of Rdg +0.7°C |
|
| |
| Temperature Accuracy °F |
| T/C Type |
Range |
Resolution |
Accuracy |
| Type K |
-328°F to 1000°F |
0.1° |
0.1% of Rdg +1.4°F |
| 1001°F to 2498°C |
1.0° |
0.1% of Rdg +1.4°F |
| Type J |
-328°F to 940°F |
0.1° |
0.1% of Rdg +1.4°F |
| 941°F to 1400°F |
1.0° |
0.1% of Rdg +1.4°F |
| Type T |
-328°F to 730°F |
0.1° |
0.1% of Rdg +1.4°F |
| Type R |
32°F to 1000°F |
0.1° |
0.1% of Rdg +1.4°F |
| 1001°F to 3200°F |
1.0° |
0.1% of Rdg +1.4°F |
| Type S |
32°F to 1000°F |
0.1° |
0.1% of Rdg +1.4°F |
| 1001°F to 3200°F |
1.0° |
0.1% of Rdg +1.4°F |
| Type E |
-328°F to 720°F |
0.1° |
0.1% of Rdg +1.4°F |
| 721°F to 1832°F |
1.0° |
0.1% of Rdg +1.4°F |
|
| |
| |
| General Specifications |
| Operating Temperature |
0 °C to 50 °C
(32 °F to 122 °F) at 0 to 85 % R.H. (non-condensing) |
Ambient Coefficient
|
0 °C to 18 °C
and 28 °F to 50 °C (ambient temperatures) for each °C ambient below
18 °C or above 28 °C, add the following tolerance into the accuracy
spec: 0.01 % of reading +0.03 °C (0.01 % of reading +0.06 °F) |
|
| |
|
Included Accessories |
|
Complete with two K-type bead probes,
Hard carrying
case, batteries and users manual. |
|
| |
| |
|