The Amprobe TX900 microwave leakage detector has
been designed to assist domestic and commercial appliance engineers
with microwave ovens. The Amprobe TX900 can be used to verify if the
oven operates in accordance with current standards and regulations.
Features
Measures for wave leakage and tests oven power.
8 dipole sensors - allows detection of plane wave signals of
any polarization.
Temperature compensation - accurate reading regardless of
ambient temperature changes.
Compact, ergonomic design.
Low battery indication.
Digital and Analog Bar Graph Display.
Auto-zero.
Accessories supplied: Two 500ml Plastic Beakers, Spirit
(alcohol) Glass Thermometer, 9 volt Battery, Carrying Case, and
Sample set of "RF Emission Labels."
Electrical Specification
RF Power Sensing Range
0 to 10mW/cm2
Nominal Detecting Frequency
2.45 GHz
Calibration Accuracy
± 1dB in plane wave - circular polarization
Response to Step Input
< 1 second
Resolution
0.1 mW/cm2
General Specification
Display
2-1/2 Digit LCD with 10 point bargraph display
Power Source
9 Volt NEDA 1604A/IEC 6LR61 Battery
Low Battery
6 Volts Approximately
Nominal Current
10mA
Sensor - Source Spacing
Circular - 5cm
Environmental
Indoor operation
Altitude
Below 2000 meters
Operating Temperature
0°C to 50°C (32°F to 122°F). < 80% RH
Storage Temperature
-20°C to 50°C (-4°F to 122°F). < 80% RH
(with battery removed)
Dimensions
230mm (L) x 44mm (W) x 42mm (D)
Weight (Instrument Only)
150g
Safety CEEMC
EN 61326-1:2006
This product complies with requirements of the
following European Community Directives: 2004/108/EC
(Electromagnetic Compatibility) and 2006/95/EC (Low Voltage) as
amended by 93/68/EEC (CE Marking). However, electrical noise or
intense electromagnetic fields in the vicinity of the equipment may
disturb the measurement circuit. Measuring instruments will also
respond to unwanted signals that may be present within the
measurement circuit. Users should exercise care and take appropriate
precautions to avoid misleading results when making measurements in
the presence of electronic interference.
Standard Accessories
TX-900 Microwave RF Detector Instrument:
Included with Instrument; 2 x 500ml Plastic Beakers,
Spirit (alcohol) Glass Thermometer, 9 volt PP3 type battery,
Carrying case, Sample set of "RF Emission Labels",
Registration Card, Certificate of Conformance, and Owner's
Manual.
Obiat Pty. Ltd.
A.C.N. 003 166 952
A.B.N. 23 003 166 952
Unit 9A/8 Avenue of the Americas, Newington NSW 2127 Australia
P.O. Box 6901 Silverwater NSW Australia 1811