Take a
new look at current measurement
With the striking design of
the Fluke 330 Series, we've taken a new look at the way you make current
measurements. At how you use your tools, and how to get the results you
need, faster and more conveniently. The result is a new, ergonomic
concept, shaped to fit your hand and to access tight spots easily. The
series feature a large display that is backlit -on most models- so
readings can be taken in virtually any lighting situation.
|
|

  |
|

-
Fluke
333 - Rugged reliability at a basic price, measures ac amps, ac/dc volts
and ohms.
-
Fluke
334 - Large display with backlight, measures ac amps, ac/dc volts, ohms
and motor start-up current.
-
Fluke
335 - A True-rms clamp meter, large backlit display, measures ac amps,
ac/dc volts, ohms and motor start-up current.
-
Fluke
336 - A True-rms clamp meter that measures ac/dc current and voltage,
ohms, motor start-up current with large display and backlight.
-
Fluke
337 - The top-of the-line True-rms clamp meter, large jaw measures ac/dc
current and voltage, ohm, motor start-up current (in-rush), frequency,
MIN/MAX capability and a large backlit display.
|
|
|
| |
| |
 |
| |
|
Voltage DC |
Range: 0 - 600.0 V
Accuracy: 1% ± 5 counts |
|
Voltage AC |
Fluke 333/334
Range: 0 - 600.0 V
Accuracy: 1% ± 5 counts (50/60 Hz)
AC Response: Averaging
Fluke 335
Range: 0 - 600.0 V
Accuracy: 1% ± 5 counts (50/60 Hz)
AC Response: True-rms
Fluke 336/337
Range: 0 - 600.0 V
Accuracy: 1% ± 5 counts (20-100 Hz), 6% ± 5 counts
(100-400 Hz)
AC Response: True-rms |
|
Current DC |
Fluke 336
Range: 0 - 600.0 A
Accuracy: 2% ± 3 counts
Fluke 337
Range: 0 - 999.9 A
Accuracy: 2% ± 3 counts |
|
Current AC |
Fluke 333/334
Range: 0 - 400.0 A
Accuracy: 2% ± 5 counts (50/60 Hz)
AC Response: Averaging
Fluke 335
Range: 0 - 600.0 A
Accuracy: 2% ± 5 counts (50/60 Hz)
Crest Factor(50/60 Hz):
2.4 @ 500A, 2.0 @ 600A, add 2% for CF>2
AC Response: True-rms
Fluke 336
Range: 0 - 600.0 A
Accuracy: 2% ± 5 counts (10-100 Hz),
6% ± 5 counts (100 - 400 Hz)
Crest Factor(50/60 Hz):
3 @ 500A, 2.5 @ 600A, add 2% for CF>2
AC Response: True-rms
Fluke 337
Range: 0 - 999.9 A
Accuracy: 2% ± 5 counts (10-100 Hz),
6% ± 5 counts (100 - 400 Hz)
Crest Factor(50/60 Hz): 3 @ 500A,
2.5 @ 600A, 1.42@1000 A, add 2% for CF>2
AC Response: True-rms |
|
Resistance |
Fluke 333
Range: 0 - 600.0 W
Accuracy: 1.5% ± 5 counts
Fluke 334/335/336/337
Range: 0 - 600.0 W, 6001 -
6000 W
Accuracy: 1.5% ± 5 counts |
|
Frequency |
Fluke 337
Range: 5 - 400Hz
Accuracy: 0.5% ± 5 counts
Trigger Level:
10-100 Hz >= 5A, 5-10 Hz, 100-400 Hz >=10A |
|
Inrush Current |
Fluke 334/335/336/337
Integration Time: 100 ms |
|
Continuity |
≤
30
W |
|
MIN/MAX |
Fluke 337
only |
|
| |
| |
 |
| |
|
Operating Temperature |
-10°C to
+50°C |
|
Storage Temperature |
-40ºC to
+60ºC |
|
Operating Altitude |
2,500
meters |
|
Temperature De-rating |
Add 0.1 x
specified accuracy for each ºC above 28ºC or below 18ºC |
|
| |
| |
 |
| |
|
Safety Rating |
IEC
1010-2-032, 600V CAT III |
|
| |
| |
 |
| |
|
Size |
Fluke 333/334/335
240 x 80 x 40 mm
Fluke 336/337
250 x 80 x 40 mm |
|
Weight |
310 g |
|
Warranty |
Three
years |
|
Battery life |
Alkaline
approximately 150 hours continuous
Automatic low battery indicator |
|
Backlight |
Fluke
334/335/336/337 |
|
Display Hold |
Yes |
|
| |
| |
 |
| |
|
Model Name |
Product
Description |
Fluke Model 333
Fluke Model 334
Fluke Model 335
Fluke Model 336
Fluke Model 337
|
Clamp
Meter
All Models Include the following Accessories
- Coated instruction card
- Safety information sheet
- Soft carrying case
- TL75 test leads
- Two AA Alkaline batteries
|
|
| |
| |
 |
| |
|
|
|