Specifications |
|
Inputs |
4 voltage and current (3
phases + neutral) |
|
Maximum Voltage |
1000 Volts Rms (6kV peak) |
|
Maximum Sampling Speed |
200 kS/s on each channel
simultaneously |
|
| |
| |
|
Volt/Amps/Hertz |
Measurement
Range |
Accuracy
|
|
Vrms (AC + DC) |
1 to 1000V |
0.1% of Vnom |
|
Vpeak |
1 to 1400V |
5.0% of Vnom |
|
Crest Factor, Voltage |
1.0 to >2.8 |
±5% |
|
Arms (AC + DC) |
0 to 20kA |
±0.5%
of rdg ±5 counts |
|
Apeak |
1.4x rms value |
5% |
|
Crest Factor (A) |
1 to 10A |
±5% |
|
Hz 50Hz Nominal |
40Hz to 70Hz |
±0.01Hz |
|
| |
| |
|
Dips and
Swells |
Measurement
Range |
Accuracy
|
|
Vrms (AC + DC) Note2 |
0.0% to 100% of Vnom |
±0.2%
of nominal voltage |
|
Arms (AC + DC) Note2 |
0 to 20kA |
±1% of
rdg ±5 counts |
|
| |
| |
|
Harmonics |
Measurement
Range |
Accuracy
|
|
Interharmonic (n) |
DC, 1 to 50; (Off, 1 to 49)
measured according to IEC 61000-4-7 |
|
Vrms |
0.0 to 1000V |
±0.05%
of nominal voltage |
|
Arms |
0.0 to 4000mV x clamp
scaling |
±0.5%
of rdg ±5 counts |
|
Watts |
Depends on clamp scaling and
voltage |
±5% ±n
x 2% of rdg ±10 counts |
|
DC Voltage |
0.0 to 1000V |
±0.2%
of nominal voltage |
|
THD |
0.0 to 100.0% |
±2.5% V
and A (±5% Watt) |
|
Hz |
0 to 3500Hz |
±1Hz |
|
Phase Angle |
-360°
to +360° |
±n x
1.5° |
|
| |
| |
|
Power and
Energy |
Measurement
Range |
Accuracy
|
|
Watt, VA, VAR |
1.0 to 20.00 MVA
Note1 |
±1% of
rdg ±counts |
|
kWh, kVAh, kVARh |
00.00 to 200.0 GVAh
Note1 |
±1.5%
of rdg ±10 counts |
|
Power Factor/Cos Ф/DPF |
0 to 1 |
±0.03 |
|
| |
| |
|
Unbalance |
Measurement
Range |
Accuracy
|
|
Volts |
0.0 to 5.0% |
±0.05% |
|
Current |
0.0 to 20% |
±1% |
|
| |
| |
|
Logging |
|
|
|
Sampling |
5 readings/second,
continuous sampling per channel |
|
Readings |
User selectable up to 100
readings on 3 phases and neutral simultaneously |
|
Averaging |
2 hour down to 0.5 second
user selectable |
|
Memory |
User selectable up to 7MB of
shared memory |
|
Recording Time |
User selectable, depends on
selected number of readings |
|
Zoom |
Yes |
|
| |
| |
|
Autotrend
Recording |
|
|
|
Sampling |
5 readings/second,
continuous sampling per channel |
|
Memory |
1800 minimum, maximum and
average points for each reading |
|
Recording Time |
up to 450 days |
|
Zoom |
Up to 12x horizontal zoom |
|
| |
| |
|
Memory |
|
|
|
Screens and Data |
50, shared memory divided
between logging, screens and data sets |
|
| |
| |
|
Notes |
|
|
|
Note1 |
Depending on Clamp Scaling |
|
Note2 |
Value is measured over 1
cycle, commencing at a fundamental zero crossing, and
refreshing each half-cycle. |
|
| |
| |
|
Environmental
and Safety |
|
Operating Temperature |
0°C to
50°C |
|
Safety |
EN 61010-1 (2nd edition)
pollution degree 2; 1000V CAT III/ 600V CAT IV
ANSI/ISA S82.01 |
|
| |
| |
|
Mechanical
and General Specifications |
|
Power Supply |
Rechargeable NiMH pack
(installed) |
|
Battery Life |
greater than 7-hours |
|
Battery Charging Time |
4-hours typical |
|
Shock and Vibration |
Shock: 30g
Vibration: 3g according to MIL-PRF-28800F Class 2 |
|
Case |
Rugged shock proof with
integrated protective holster, IP51 (drip and dust
proof). |
|
Size |
256mm (L) x 169mm (W) x 64mm
(D) |
|
Weight |
2kg |
|
Warranty |
3-years |
|