Model 707Ex Loop Calibrator |
| |
| The fast
one-handed tool for mA loop checks in Ex zones . |
|
|
The 707Ex is an intrinsically safe loop calibrator for use in
explosion endangered areas. The Fluke 707Ex is certified in
accordance with the ATEX directive (Ex II 2 G Eex ia IIC T4) in
Zones 1 and 2.
|
|

|
Features
- Large display and simple, quick-click
push rotary button for easy one-handed operation.
- Simultaneous mA and % readout for quick,
easy, interpretation of readings.
- mA accuracy of 0.015%, superior to other
loop calibrators.
- 1 µA resolution for mA source, simulate
and measure.
- Push button with 25% steps for fast,
easy linearity checks.
- 0-100% "span check" for fast
confirmation of zero and span.
- Selectable slow ramp, fast ramp, and
step ramp to provide smooth outputs for valve slewing and loop
functional tests.
- Internal loop supply, so you can power
and read a transmitter at the same time without carrying a DMM.
- Measures Vdc to 28 V.
- Single 9 V battery that is easily
changed.
- 0-20 mA or 4-20 mA default start up
modes.
- Innovative output adjustment dial with 1
µA and 100 µA resolution.
- HART® compatible resistance is connected
in series with the loop supply for compatibility with HART
communicators.
Calibration Modules |
|
|
|
| Specifications |
|
Current
Measurement
|
|
Range: |
0 to 24mA |
|
Resolution: |
0.001mA |
|
Accuracy: |
0.015% of
Reading +2 LSD |
|
|
Current
Sourcing
|
|
Range: |
0 to 20mA or
4 to 20mA |
|
Accuracy: |
0.015% of
Reading +2 LSD |
|
Drive
Capability: |
700Ω
at 20mA |
|
|
Current
Simulation
|
|
Range: |
0 to 20mA or
4 to 20mA |
|
Accuracy: |
0.015% of
Reading +2 LSD |
|
|
Loop Power |
While measuring mA, 24V |
|
Voltage
Measurement
|
|
Range: |
0 to 28V dc |
|
Resolution: |
1mV |
|
Accuracy: |
0.015% of
Reading +2 LSD |
|
|
| |
|
|
| Environmental |
|
Operating
Temperature |
-10°C
to +55°C |
|
Storage
Temperature |
-40°C
to +60°C |
|
Humidity
(without condensation) |
|
0 to 95%
(0°C to 30°C) |
|
0 to 75%
(30°C to 40°C) |
|
0 to 45%
(40°C to 50°C) |
|
|
Temperature
Coefficient |
|
-10°C
to +18°C |
±005% of Range per
°C |
|
28°C
to 55°C |
|
|
| |
| |
| Safety |
|
Safety |
CSA C22.2
No. 1010.1: 1992 |
|
EMC |
EN50082-1: 1992
and EN55022: 1994 Class B |
|
Maximum Voltage |
30V (protection
circuit for 230V |
|
ATEX
Certification |
Ex II G Eex ia IIC
T4 Zones 1 and 2,
ZELM 02 ATEX 0120X |
|
CE
Certification |
EN61010-1 and
EN61326 |
|
| |
|
|
| General Specifications |
|
Size |
152mm x 70mm x
41mm |
|
Weight |
224gms
(350gms including holster) |
|
Batteries |
Alkaline 9Volt
battery |
|
Warranty |
One year |
|
Shock and
Vibration |
per MIL-T-28800
for Class 2 Instrument |
|
Display
Current and % of Span |
Yes |
|
Auto Step,
Auto Ramp |
Yes |
|
Span Check |
Yes |
|