Navigation: Process Calibration Tools > Model 744
   

   
 

The Fluke Model 744 offers all the capabilities of the model 743B, plus the ability to calibrate, maintain, and troubleshoot HART instrumentation. Integrated HART communication functions permit you to monitor, control, and calibrate HART instrumentation. It handles fast pulsed instruments, RTD transmitters and PLC's, with pulses as short as 1ms.
 

  • Integrated HART communication functions, permitting you to monitor, control, and calibrate HART instrumentation.
  • Handling of fast pulsed RTD transmitters and PLCs, with pulses as short as 1 mS.
  • NiMH battery with 3500 mA hour life and gas gauge.
  • Requires no external box or second tool for everyday HART calibration and maintenance.
  • Offers fast HART communication.
  • Supports popular models of HART transmitters, with more devise-specific command support than any other HART field calibrator.
  • Fully complies with the Data Link Layer of the HART protocol, including multiple masters, burst mode, and multi-drop configurations.
  • Is easy to update as additional instruments are added and new HART versions are released.
  • Is based on the 743B, the most rugged, reliable multifunction field calibrator available.
  • Is backed by the service and support of the Fluke organization, a member of the Hart Communications Foundation.

The 744 is designed to take on nearly all the day-to-day tasks you now perform with a separate communicator. In fact, it offers the communication capabilities of the 275 HART communicator except for the DD interpreter, which can read command set libraries from any HART supplier. This is not necessary for daily HART maintenance.

With the 744 DPC, you can:
Generate precision electrical, temperature, or pressure signals for analog stimulus or sensor simulation.

Simultaneously measure electrical, temperature, or pressure signals from transmitter output.

Determine type, manufacturer, model, tag ID by interrogating HART devices.

Read HART PV function and smart transmitter digital output while measuring analog mA output.

Read and write HART configuration functions to make field adjustments to PV range points, damping, and other top-level configuration settings.

  • Re-label smart transmitters by reading and writing HART tag and message fields.
  • Clone additional transmitters by reading and storing basic HART configurations.
  • Perform automated HART sensor trim and output trim for selected devices in conjunction with As Found/As Left tests.
  • Perform loop test with simultaneous analog and digital mA readout.
  • Address new, fast, pulsed-excitation smart transmitters and PLCs.

Instrumentation management software:
The Fluke 743B and 744 are compatible with Fluke 700SW DPC/TRACK software and with software from Blue Mountain, Cornerstone, Fisher-Rosemont, Honeywell, On Time Support and Prime Technologies.
 

 
Function Measure Sourcing
DC Voltage 0.025% of reading + 0.005% full scale 0.01% of output + 0.005% full scale
DC Current 0.01% of reading + 0.015% full scale 0.01% of output + 0.015% full scale
Resistance 0.05% of reading + 50mΩ 0.01% of output + 40mΩ
Frequency 0.05% 0.01%
Thermocouples 0.3°C 0.2°C
RTDs 0.3°C 0.1°C
Pressure

To 0.05% of full scale, per Pressure Module specifications

Summary specifications: best case, midrange, one-year.
 
 
 
General Specifications
Dimensions 130mm x 236mm x 61 mm
Weight 1.4 kg (3 lb 1 oz)
Internal Battery Pack NiMH 7.2V, 3500 mAh
Battery Life Typical usage > eight hours
Battery Replacement Via snap-shut door without opening calibrator; no tools required
Side Port Connections
  • Pressure module connector
  • RS-232 connector to interface to your PC
  • Connection for optional battery eliminator
Safety Complies with CAN/CSA C22.2 No 1010.1-92, ASNI/ISA S82.01-1994, UL3111, and EN610-1:1993
Data Storage Capacity 1 week of calibration results
90 day specifications The standard specification intervals for the 744 is 1 and 2 years. Typical 90 day measurement and source accuracy can be estimated by dividing the one year "% of reading" or "%of output" specifications by 2. Floor specifications, expressed as "% of f.s." or "counts" or "ohms" remain
 
Fluke 700 Series Pressure Modules
  • 29 pressure modules.
  • Ranges from 1.000 in (0.2491 kPa) to 10,000 psi (68.948 MPa).
  • Gage, differential, dual (compound), absolute, & vacuum modules.
  • Rugged cases protect the modules from harsh environments.
  • Full-accuracy performance from 0°C to 50°C
  • Pressure readings update twice per second, and may be displayed in up to 11 different units.

  • One year warranty
    Fluke 700 Series Pressure Modules and Pump Kits.

 
 
 
Model Description
Fluke 744
 

 

 

 


 

Documenting Process Calibrator, including
Model TL24 Industrial test leads (two sets).
Model AC20 test clips (two sets).
Model TP20 test probes.
Model BP7235 NiMH battery pack
Model BC7217 battery charger.
Instruction manual.
HART user's manual
NIST Traceable calibration certificate and data three year warranty.
Serial port cable, HART communications cable,
DPC/TRACK Sample Version with free PC communication utility software.


 

AEMC | AMPROBE | CIE | FLUKE | HT ITALIA | HODEN | PROVA | POMONA | RAYTECH |  SILVERTRONIC
Home | PRODUCTS | SEARCH
Obiat Pty. Ltd.
A.C.N. 003 166 952      A.B.N. 23 003 166 952
Unit 9A/8 Avenue of the Americas, Newington NSW 2127 Australia
P.O. Box 6901 Silverwater  NSW Australia 1811

Phone: 61-2-9748- 8699

Fax: 61-2-9748-8544

E-mail:
 

 information@obiat.com.au
sales@obiat.com.au

Copyright ©                                             Last Update: Wednesday, 13 April 2011