Model 902
HVAC Clamp Meter |
| |
True-rms HVAC Clamp Meter
The Fluke 902 True RMS HVAC Clamp Meter provides the accuracy,
reliability and ruggedness that defines Fluke test tools. It is
designed for HVAC technicians for the systems they service and
install daily. With True RMS technology and a CAT III 600V rating,
HVAC technicians can troubleshoot and maintain HVAC equipment safely
and with confidence in the results.
Use the Fluke 902 to get more done:
- Capture flue gas temperatures.
- Conduct flame rod testing.
- Measure start and run motor capacitors.
- Measure supply side current and voltage as well as load side
current and voltage.
- Measure current and voltage phase balance on 3 phase systems.
- Troubleshoot compressor electrical motor faults.
- Measure performance of variable frequency drives.
|
 |
Features
- Designed for HVAC applications with capacitance, DC Current
(µA), and temperature measurements.
- Small body and jaws fit perfectly in your hand and into tight
places.
- Handy 'Display Hold' button keeps measurements on the display.
- Meter controls are positioned so current measurements can be
done with one hand (index finger on clamp opening lever and thumb
on rotary switch).
- Large, backlit display is easy-to-see in less than ideal
conditions.
- Auto shut-off maximizes battery life so the meter works when
you need it.
- Three year warranty.
|
|
| |
| Specifications |
|
Voltage DC |
|
Range: |
0 to 600.0V |
|
Accuracy: |
1% ±5 counts |
|
|
Current DC |
|
Range: |
0 to 200uA |
|
Accuracy: |
1% ±5 counts |
|
|
Voltage AC (True-rms) |
|
Range: |
0 to 600.0V |
|
Accuracy: |
1% ±5 counts (50/60Hz) |
|
|
Current AC (True-rms) |
|
Range: |
0 to 600.0A |
|
Accuracy: |
2% ±5 counts (50/60Hz) |
|
|
Resistance |
|
Range: |
0 to 9999Ω |
|
Accuracy: |
1.5% ±5 counts |
|
|
Capacitance |
|
Range: |
1 to 1000 uF |
|
Accuracy: |
1.2% ±2 counts |
|
|
Continuity |
≤ 30Ω |
|
Temperature (type 'K' Thermocouple)
|
|
Range: |
-10°C to 400°C
(-14°F to 752°F) |
|
Accuracy: |
±1.0% + 0.8°C (±1.0% + 1.5°F)
typical |
| |
|
|
Range: |
-40°C to -10°C
(-40°F to 14°F) |
|
Accuracy: |
±5.0% + 1.5°C (±5.0% + 3.3°F)
typical |
|
|
| |
|
|
| General Specifications |
|
Dimensions |
27.3cm (L) x 10.8cm (W) x 6.2cm (D) (10.75" x 4.25" x 2.44") |
|
Weight |
7 kg (1.5lbs) |
|
Battery Type |
Two type AA Alkaline batteries |
|
| |
|
|
| Ordering Information |
| Model Name |
Description |
| Model 902 |
True-rms HVAC Clamp Meter
Includes:
- AA Alkaline batteries (qty.2).
- Users manual w/safety information.
- Soft carrying case.
- TL75 Test Leads (1 pair).
- 80BK Integrated DMM Temperature Probe (qty.1).
|
|