Prova 6200 Graphic Power Quality Analyzer Features
  • Analyzer for Single-Phase and Balanced Three-Phase Systems.
  • Harmonic Analysis of Voltage and Current (1 to 50th order).
  • True-RMS measurement of Volts with 0.5% of reading basic accuracy.
  • True-RMS measurement of Amps with 2% of reading basic accuracy.
  • Graphic Waveform of Voltage and Current.
  • Transient Detection and Logging of Swell, Dip, and Outage.
  • Active Power (W, KW, MW, GW).
  • Apparent (VA, KVA, MVA).
  • Reactive Power (VAR, KVAR, MVAR).
  • Measure Power Factor and Phase Angle.
  • Energy (WH, KWH, KVARH, PFH).
  • Programmable VT ratio from 1 to 3000.
  • Display of Overlapped Voltage and Current Waveform.
  • Maximum Demand (MD in W, KW, MW) with Programmable Period.
  • Harmonic Analysis (V and I) to the 50th Order.
  • Data Hold functions.
  • Auto power Off function in 15 minutes (selectable).
  • Optional isolated USB data connection.
  • Unlimited data logging facility using a PC.
  • Analyzer supplied with: User's Manual, Software User's Manual, Software CD, Test Leads, Alligator Clips, RS232 to USB Bridge, two 1.5 volt Batteries and Carrying Bag.
  • Display of 25 Harmonics in One Screen.
  • Data-logging of 32, 64, 128, or 256 points/cycles.
  • Analysis of Total Harmonic Distortion (%THD-F).
  • Graphic Phasor Diagram.
  • Capture 128 Transient Events (Time + Cycles + Faults) with Programmable Threshold (%), also can be reviewed in LCD display.
  • 50,000 Records with Programmable Interval (1 to 6,000 seconds).
  • Real-time Output of Waveform, Power Parameters and Harmonics at Command.
  • Large LCD Display with Backlight.
  • Optical Isolated RS-232C Interface.
  • Power saver for Long-term Monitoring.
  • Built-in Calendar/Clock for Data Logging.
Specifications Prova 6200 Datasheet (PDF)

 

General Specifications

Conductor Size

Cable diameter 55mm approx.
Bus Bar 65mm x 24mm

Range Selection

Auto

Display

128 x 64 Dot Matrix LCD with Backlight

LCD Update Time

2 times/second

Number of Samples per Period

512 samples (voltage or current)
256 samples (power)

Altitude

up to 2000 meters

Power Supply

Two 1.5 volt batteries

Power Consumption

10mA (approx.)

Auto Power Off

After 15 minutes

Overload Indication

Yes , (OL)

Operating Temperature

-10°C to 50°C

Storage Temperature

-20°C to 60°C

Operating Humidity

Less than 85% relative

Storage Humidity

Less than 75% relative

Dimensions

271mm (L) x 112mm (W) x 46mm (D)

Weight

647g (batteries included)

 

AEMC | AMPROBE | CIE | FLUKE | HT ITALIA | HODEN | PROVA | POMONA | RAYTECH |  SILVERTRONIC
Home | PRODUCTS | SEARCH
Obiat Pty. Ltd.
A.C.N. 003 166 952      A.B.N. 23 003 166 952
Unit 9A/8 Avenue of the Americas, Newington NSW 2127 Australia
P.O. Box 6901 Silverwater  NSW Australia 1811

Phone: 61-2-9748- 8699

Fax: 61-2-9748-8544

E-mail:
 

 information@obiat.com.au
sales@obiat.com.au

Copyright ©                                             Last Update: Sunday, 01 May 2011