Prova 6601 Three-Phase Power Clamp Features
  • KW, PF/COSФ, KVA, KVAR, (3Ф4W, 3Ф3W, 1Ф).
  • AC+DC True Power, True-Rms, AC volts, AC current.
  • AC+DC 1200KW (1Ф), AC + DC 2000KW (3Ф)
  • Dual Display KW+PF, KVA+KVAR, V+Hz, A+V.
  • Cable Diameter 55mm.
  • Bus-Bar 65mm (D) x 24mm (W).
  • Auto Rang V, A, W: AC/DC Auto Detection.
  • Memory of 4 records.
  • Auto ranging.
  • AC/DC Auto Detection.
  • Clamp Meter supplied with: User's Manual, 9-volt Battery installed, and Carrying Bag.


    Prova 6601 Datasheet (PDF)
 
Specifications
 
(23°C ±5°C)
 
AC+DC True Power
(PF 0.2 - 1.0, 3Ф3W, 3Ф4W, 1Ф2W and 1Ф3W)
Range Resolution Accuracy Range
0 to 99.99KW 0.01KW ±2.0% of reading ±0.05KW

AC600V, DC800V,
ACA/DCA2000A

100 to 999.9KW 0.1KW ±2.0% of reading ±0.5KW

AC600V, DC800V,
ACA/DCA2000A

1000 to 1200KW 1KW ±2.0% of reading ±5KW

AC600V, DC800V,
ACA/DCA2000A

 
 
KW Autoranging Map
(PF 0.2 - 1.0, 3Ф3W, 3Ф4W, 1Ф2W and 1Ф3W)
  0V to 200V 200V to 600V AC
200V to 800V DC
0A to 200A 0.00 to 40.00KW 0.00 to 99.99KW
100.0 to 160.0V DC
200A to 2000A 0.0 to 400.0KW 0.0 to 999.9KW
1000 to 1600KW
 
 
AC+DC Voltage (True RMS, Crest Factor <4, Autorange
Overload Protection 800Volts AC for all ranges)
Range Resolution Accuracy of reading Input
Impedance
DC, 50/60Hz 40 to400Hz
0 to 200V 0.1V ±1.5% ±5dgts ±2.0% ±5 dgts 10MΩ
200 to 500V 0.1V ±1.5% ±5dgts ±2.0% ±5 dgts 10MΩ
500 to 600V 1V ±1.5% ±5dgts ±2.0% ±5 dgts 10MΩ
 
 
AC+DC Current (True RMS, Crest Factor <4)
Range Resolution Accuracy of reading Overload
Protection
DC, 50/60Hz 40 to400Hz
0 to 200A 0.1A ±1.5% ±5dgts ±2.0% ±5 dgts 3000A AC
200 to 500A 0.1A ±2.0% ±5dgts ±2.5% ±5 dgts 3000A AC
500 to 2000A 1A ±2.0% ±5dgts ±3.0% ±5 dgts 3000A AC
 
 
Frequency (if <10Hz, Hz=0)
Range Accuracy Sensitivity
50/60Hz ±2 digits V: >1V, A: >5A
10 to 1000Hz ±1.5% ±2dgts V: >1V, A: >5A
 
 
AC+DC KVAR
Reactive Power, 3Ф3W Sine Wave
Range Resolution Accuracy Range
0 to 99.99KW 0.01KW ±2.0% of reading ±0.05KW

AC600V, DC800V,
ACA/DCA2000A

100 to 999.9KW 0.1KW ±2.0% of reading ±0.5KW

AC600V, DC800V,
ACA/DCA2000A

1000 to 1200KW 1KW ±2.0% of reading ±5KW

AC600V, DC800V,
ACA/DCA2000A

 

General Specifications

Conductor Size

Cable diameter 55mm approx.
Bus Bar 65mm x 24mm

Range Selection

Auto

Display

2 rows 4 digits Dual Display LCD

Sampling Time

0.5 second volts and current
1.6 seconds (power)

Altitude

up to 2000 meters

Power Supply

9 volt battery

Power Consumption

25mA (approx.)

Low Battery Indication

Yes

Overload Indication

Yes , (OL)

Operating Temperature

4°C to 50°C

Storage Temperature

-20°C to 60°C

Operating Humidity

Less than 85% relative

Storage Humidity

Less than 75% relative

Dimensions

271mm (L) x 112mm (W) x 46mm (D)

Weight

647g (batteries included)

 

 

AEMC | AMPROBE | CIE | FLUKE | HT ITALIA | HODEN | PROVA | POMONA | RAYTECH |  SILVERTRONIC
Home | PRODUCTS | SEARCH
Obiat Pty. Ltd.
A.C.N. 003 166 952      A.B.N. 23 003 166 952
Unit 9A/8 Avenue of the Americas, Newington NSW 2127 Australia
P.O. Box 6901 Silverwater  NSW Australia 1811

Phone: 61-2-9748- 8699

Fax: 61-2-9748-8544

E-mail:
 

 information@obiat.com.au
sales@obiat.com.au

Copyright ©                                             Last Update: Sunday, 08 May 2011