Model AFLEX 3002
Flexible AC Current Clamp |
| |
| Flexible probe, different from normal clamp meters, can pass through
obstacles at will and wind many conducting wires simultaneously, maximum
diameter 170mm. |
 |
Features
- AC Current 3000A True RMS 50/60Hz.
- AC Voltage 600V True RMS.
- Fast Peak Function.
- Max/Min.
- Auto-Power Off: after 30 minutes.
|
|
|
Specifications |
(23°C
±5°C) |
|
|
AC Current 50/60Hz, Auto Range, True RMS, Crest
Factor <4, CT=1, Conductor is located at the centre of flexible loop.
Position sensitivity is 2% of range. External field effect of <40A/m and
200mm from the coupling is 1% of range. Temperature coefficient is 0.02%
of reading/°C)
|
| Range |
Resolution |
Accuracy of
Readings1 |
| 0 to 300.0A |
0.1A |
±1% of range |
| 300.0 to 999.9A |
0.1A |
±1% of range |
| 1000 to 3000A |
1A |
±1% of range |
|
Note1: For CT°/1,
the accuracy in percentage is the same (±0.5%).
But the additional digits should be multiplied by the CT ratio.
For example, ±5 digits becomes ±5
digits times CT ratio. |
| |
AC Voltage 50/60Hz, Auto Range, True RMS, Crest
Factor <4, Input Impedance 10MΩ, Overload Protection
800V AC.
|
| Range |
Resolution |
Accuracy of
Readings1 |
| 4.0V to 600.0V |
0.1V |
±0.5% ±5 digits |
|
| |
Frequency (RMS value) or ACA (RMS value > 30A)
|
| Range |
Resolution |
Accuracy of
Readings1 |
| 45Hz to 65Hz |
0.1Hz |
±0.2Hz |
|
| |
|
|
|
General Specifications |
|
Probe Length: AFLEX 3002-24 |
24 inches (610mm) |
|
Minimum Bending Diameter |
35mm |
|
Probe Connector Diameter |
23mm |
|
Cable Probe Diameter |
14mm |
|
Cable Length/Probe to Instrument |
170mm |
|
Instrument Dimensions |
130mm (L) x 80mm (W) x 43mm (H) |
|
Battery |
Two 1.5V SUM-3 |
|
Display |
LCD 4 + 4 digits |
|
Range Selection |
Auto |
|
Temperature (Operating) |
-10°C to 85°C |
|
Humidity (Operating) |
15% to 85% RH |
|
Altitude |
2000 Meters |
|
Weight |
430g (battery included) |
|